☆ Application: Eaton dual-clutch transmission valve body test station C
☆ Function: leak detection test
☆ Workpiece loading: manual load/unload
☆ Master control: differential-pressure leak tester
☆ Cycle time: 1 minute
☆ Control system: PLC operated
☆ Drive system: pneumatic
☆ Audio-visual alarm: mistake-proof alarm system + indicator light with buzzer
☆ Safety protection: safety light curtain
| Technical Specifications |
| Differential pressure | Min. display value | 0.1Pa (standard) |
| Display accuracy | ±5% of R.D. ±1Pa | |
| Display range | 999Pa standard (±1.5kPa when kPa unit is selected) | |
| Sensor pressure rating | 5MPa | |
| Display units | Test pressure | kPa, MPa (kg/cm2, PSI and other non-SI units available for overseas users) |
| Leak rate | mL/min, mL/s, Pa, kPa (mmH2O and other non-SI units available for overseas users) | |
| Leak rate display | 3 digits (shiftable decimal point), 10 responses/sec | |
| Channels | 32ch (0–31) | |
| Time setting range | 999.9 s (0.1 s resolution) | |
| Power supply | AC100~240V±10%, 50/60Hz, 100VAmax | |
| Test pressure source | Use clean air; the source pressure must be well above the test pressure. | |
| Drive pressure source | 400–700kPa clean air; use 500–700kPa air for high-pressure applications. | |
| CPU | 16-bit CPU | |
| Piping diameter | Rc1/4 (air source, test piece & master part piping) Rc1/8 (drive pressure source) |
|
| Ambient temperature | 5~40℃ (Note) Please consult us when using the instrument under high-temperature conditions. |
|
| Humidity | Below 80%RH | |
| Weight | Approx. 9kg | |
| Serial interface COM1 (RS-232C) (selectable output format) | I/F, ID/F fixed length Output selection setting |
Also outputs setting values in addition to leak data. |
| T/F fixed output Standard setting |
Outputs leak data only — same as our DF/MC/DC-720 controller. | |
| Printer interface: CENTRONICS | (Output data) Judgment result, leak rate, corrected test pressure value, WK#, CH# and others. | |
| Analog output | Differential pressure: F.S. 1VDC; Test pressure: F.S. 1VDC | |
| Accessories | Oil mist separator (except for high / extra-high pressure models), mounting bracket, communication interfaces, power cord (3m), inspection report, operation manual. |