The short answer is ultrasonic metal welding — no solder, no flux, and no melting. The welder sends high-frequency vibration into the contact area between the braid and the terminal, and under pressure the friction fuses the copper strands at the molecular level. The finished joint conducts well, with very low resistance, and suits new-energy copper braided straps, automotive wire harnesses and soft connections in switchgear.
1. Why not solder?
Soldering heats the joint to melt solder, and the solder itself adds contact resistance, while the heat can damage nearby insulation. Ultrasonic metal welding is a near-cold process: no electric current passes through the workpiece, there are no sparks and no filler is needed, and because the metal never melts, the copper keeps its original properties instead of turning brittle. A finished joint has no solder layer either, so there is no solder ageing or cracking to worry about, and less heating under continuous current. It is also fast — a weld typically takes a fraction of a second to a few seconds — which suits volume production.
2. How are the braid and terminal welded?
The usual practice is to stack the end of the copper braid with a copper terminal in the weld zone. Once the horn clamps down, ultrasonic vibration compacts the loose strands and fuses them into a single solid joint. Before welding, comb the braid straight and trim the end square; loose strands must be gathered into the weld zone, because strands left outside will not fuse and can snag other parts. This is how new-energy copper braided straps are joined to silver-plated terminals, and how soft connections for batteries and switchgear are made. A finished joint looks like a flattened solid block of metal, with no loose strands sticking out.
3. What should buyers watch?
First, the material condition. Bare copper braid welds best; some references report that a tin plating can interfere with ultrasonic welding, so tinned braid should always be validated with a trial weld on the actual parts. Second, match the cross-section: the thicker the braid and the larger the terminal, the more welding energy is needed, so the machine should be selected by braid cross-section and terminal size. Third, the metal parts should not be too thick — as a rule of thumb, generally no more than about 5 mm — and the weld spot should not be too large, or the ultrasonic energy cannot reach through. Fourth, the horn and fixture should match the terminal shape, so the strands are pressed evenly and the joint comes out compact without broken strands. Enamelled wire needs a trial too: ultrasonic welding can strip some varnish as it welds, but how cleanly depends on the actual wire.
4. How do you check the weld?
Look first at the appearance — the joint should be compacted, with no loose strands sticking out. Then pull-test it to confirm it holds up under the forces it will see in service, and where conductivity matters, measure the joint resistance as well. Only when all three checks pass is the weld accepted. Before volume production, weld a trial batch and sample-check it; only release the batch once pull strength and resistance are stable. If you are selecting ultrasonic metal welding equipment for copper braided wire or harness terminals, feel free to contact Shanghai Jingjin for a free welding sample test.