1. Turn on the power; the indicator lights up.
    2. Turn on the generator's power switch; the power indicator lights up, the output fault indicator glows dimly, and the power adjustment knob is set to minimum.
    3. If the output fault indicator lights up during use for some reason, triggering overcurrent protection, shut down the machine, turn the power adjustment knob counterclockwise to reduce power, then restart and work.
    4. Do not run the generator for a long time with the transducer unloaded, otherwise the transducer may overheat and be damaged.
    5. During normal welding, clamp the workpiece in the welding fixture and step on the foot switch for one weld.
    6. Adjust the "weld time" knob: clockwise increases weld time, counterclockwise shortens it.
    7. Power, time and pressure are three important factors for the welding system; different workpieces need different power, time and pressure — adjust repeatedly to reach the optimal process specification.
    After use, cut off the power switch.