How to use ultrasonic plastic welding equipment:
    1. Connect one end of the cable to the output control cable connector on the generator barrel and the other end to the output control cable socket on the back of the control box, then tighten it;   
    2. Clean the contact face of the horn and attach it to the transducer on the generator barrel, then lock it with a wrench. Note: when connecting, make sure the two contact faces of the horn and the transducer fit together properly and lock them tight. Do not let an overly long connecting screw or stripped threads prevent proper locking; otherwise ultrasonic transmission will be poor and the machine may be damaged;  
    3. When installing or removing the horn, always use two wrenches to hold the horn and the transducer separately — never hold only one side while tightening or removing — to avoid damaging the hand-held generator barrel;        4. After checking that items 1 and 2 are properly installed, plug the power cord into an external power outlet and flip the power switch; the power indicator will light up;  
    5. Gently press the sonic control switch. If you can hear the "sizzling" sound the horn makes as ultrasound is transmitted to it, the machine is working normally and can be put into use;  
    6. If the machine behaves abnormally during work, never disassemble it yourself — notify the supplier or send the machine to the manufacturer for inspection and repair.
    Precautions for ultrasonic plastic welding equipment:
    1. The welder runs directly on 220 V mains power, so ground the machine properly before energizing it; ground resistance must be below 4 ohms;
    2. If mains voltage fluctuates by more than 10%, install an AC voltage stabilizer for this machine to ensure efficient, safe operation;
    3. After power-on, never place your hand under the upper weld mold, to avoid injury from high-frequency vibration and high voltage;
    4. While ultrasound is being emitted, do not let the upper weld mold touch the lower weld mold, fixtures, or the worktable, to avoid damaging machine parts;
    5. Always run a sonic test before welding — especially after changing the weld mold; this step must never be skipped;
    6. Weld molds must be designed, machined, and tuned by a professional manufacturer; otherwise the ultrasonic transducer system of the welder may be damaged;
    7. The pneumatic system of this machine uses plastic components; the external air supply pressure applied must not exceed 0.5 MPa, otherwise bursting or burnout may occur. Welding at reduced frequency produces audible noise; long-term operators are advised to wear ear protection.