Welding principle of capillary tube mesh:
Materials
All capillary tube mesh produced today uses random-copolymer polypropylene (PP-R) from Borealis. Because capillary tube mesh operates at temperatures not exceeding 40 ℃ — i.e. within the cold-water range — ordinary PP could, in principle, also be used.
The main supply/return pipes are 20×2.0 mm, and the capillary tubes are 4.3×0.9 mm. PP-R is heat-resistant, corrosion-resistant, has a low coefficient of thermal expansion and low water flow resistance, is lightweight and low in density, hygienic and non-toxic. It can be joined by electrofusion and heat fusion, and the tensile, bending and impact strength at the joint exceeds that of the pipe body itself. The connections are simple and solid with no risk of leakage, so PP-R is well suited to capillary tube mesh made primarily by welding.
Welding process:
Workpiece dimensions: main pipe 500 mm long, 20 mm diameter Capillary tube diameter: 4.85 mm
Workpiece: multiple capillary tubes welded along one side of a main pipe.
Welding method: hot-air heating
Operation: fully automatic CNC control
Workpiece material: PP-R
Equipment specifications:
A temperature-controlled hot-air system, PLC-controlled, automatically completes the heating, welding and curing programs.
Motion control: automatic PLC control with an HMI.
Overall dimensions (mm): (per final design drawings)
Total power: 8 KW
Air pressure: 0–6 kg/cm²
Hot-air power: 5 KW
Welding length: 500 mm (main pipe)
Capillary tubes: 15 pcs per 500 mm
Site requirements:
Air supply: above 6 kg/cm²
Power supply: 380 V/220 V, 20 A
Ambient temperature: 5–35
Cycle time: 2–5 min per piece
Components:
Frame: consists of the main structure and the work platform.
The work platform is the machine's main worktable; the main-pipe fixture and capillary-tube fixture are mounted on the table and moved left and right on the table by pneumatic elements.
Main-pipe fixture: holds the main pipe during welding, mounted on the right side of the worktable and driven left and right on the table by a cylinder.
Capillary-tube fixture: holds the capillary tubes during welding, mounted on the left side of the worktable and movable left and right by a cylinder.
Hot-air welding system: consists of a heating system, blower, temperature control system and multi-position air outlets. It is mounted on the worktable between the main-pipe fixture and the capillary-tube fixture, and is moved up and down by a pneumatic device.
Welding cycle:
Procedure: the operator loads the main pipe and capillary tubes into their respective fixtures, starts the machine, and the machine automatically completes workpiece heating, welding and curing; the operator then removes the welded workpiece and the next cycle begins.