I. Longitudinal Wave Sound Field
Neglecting medium attenuation, the sound pressure on the axis far from the source is inversely proportional to distance and proportional to the source area.
1. Near Field
The region near the source where wave interference produces a series of sound-pressure maxima and minima is called the near field of the ultrasonic field. Sound pressure is unevenly distributed in the near field because the distances from different points on the source to a point on the axis differ, creating path differences; when superimposed, phase differences cause interference - sound pressure reinforces at some points and cancels at others, producing the pressure maxima and minima.
Within the near field, the actual sound field differs noticeably from the ideal one: although maxima and minima still occur on the axis of the actual field, their fluctuation amplitude is smaller and the number of extreme points is significantly reduced.
2. Far Field
The region on the source axis at a distance x from the source >greater than N is called the far field. Sound pressure on the far-field axis decreases monotonically with distance. When x >3N, sound pressure is inversely proportional to distance, approximately following the spherical-wave law. When distance x is large enough, the path differences from various source points to a point on the axis are small, and so are the resulting phase differences, so interference can be neglected - hence no sound-pressure maxima or minima occur in the far field.
II. Shear Wave Sound Field
Commonly used shear-wave probes send a longitudinal wave obliquely onto an interface and use mode conversion for shear-wave testing. When the incident angle lies between the first and second critical angles, the longitudinal wave is totally reflected and only refracted shear waves exist in the second medium.
Like the longitudinal-wave sound field, the shear-wave sound field has both near and far fields due to wave interference. When x≥3N, the sound pressure on the beam axis is proportional to the source area and inversely proportional to the distance from the virtual source, similar to the longitudinal-wave field. With a given shear-wave probe crystal size, increasing the K value shortens the near-field length.