Debonding of the ultrasonic equipment's vibrator: our transducers use a dual-guarantee process of adhesive bonding plus screw fastening, so this normally doesn't happen; thanks to the screws, a debonded vibrator won't fall off the vibrating surface. A common check is to gently shake the tail of the vibrator by hand and carefully inspect the adhesive on the vibrating surface. After debonding, the ultrasonic power supply output is usually normal, but since the vibrator is poorly connected to the vibrating surface, vibration is weak, and prolonged operation may burn out the vibrator.
Debonded vibrators are troublesome to repair and generally must be sent back to the manufacturer. The most effective way to avoid debonding is to avoid impacting the vibrating surface during normal use. Perforation of the vibrating surface: after a transducer runs at full load for years, the vibrating surface may perforate due to high-frequency vibration fatigue of the stainless steel plate — this means the transducer's service life is over, and it generally must be replaced. The panel control/display section includes the generator panel's power switch, power adjustment potentiometer and power output indicator, handling the cleaner's power switching, power adjustment and output status display.
Transducer-to-power-supply matching basically works as follows: the output transformer, matching inductor and transducer form a series resonant circuit; adjusting the output transformer's tap changes the output current, and adjusting the matching inductor tunes the match. If the panel display bar shows nothing at startup, check in this order: [1] main power supply, [2] fuse at the back of the machine. If the panel display bar lights but the fan doesn't run and there's no power output, check: [1] with power off, see if the fan spins freely; [2] open the cover, check whether the main internal fuse is blown, whether the bridge rectifier is damaged, and carefully inspect the power filter capacitors for damage.
In spring and autumn, some units alarm at startup but then work normally — this mostly happens in humid weather, mainly because the driver module is sensitive to humidity and tends to false-alarm in damp environments. The fix is to place the machine in a dry environment, or drive out moisture with a hair dryer when needed. To confirm this fault, verify that the alarm occurs at startup with the ultrasonic power supply unloaded and the panel power potentiometer at minimum.