Ultrasonic horns are classified into three types by mold material:   
    1. Aluminum-magnesium alloy tooling: used for manufacturing vibration systems (boosters) and horns. This material has extremely high mechanical yield strength, high hardness, and strong thermal conductivity, making it an ideal ultrasonic tooling material; however, aluminum itself is not wear-resistant, so it suits general welding requirements.   
    2. Titanium alloy tooling: used in continuously oscillating models. It offers high toughness, good thermal conductivity, and high hardness, and costs more than aluminum-magnesium alloy, but is more durable and wear-resistant than aluminum-magnesium tooling.       
    3. Imported carbide steel tooling: imported alloy material with extremely high hardness, used for continuous welding or welding with extremely high wear-resistance requirements. It has low thermal conductivity and high mechanical loss of ultrasonic energy, but because it is wear-resistant, its operating cost is low—though its manufacturing process is relatively complex.  
    By horn wavelength, they are divided into two types:  
    1. Half-wavelength tooling  
    2. Full-wave tooling  
    3. Multi-wavelength tooling   
    Key professional parameters for evaluating ultrasonic horn quality:  
    1. Horn amplitude parameter  
    Amplitude is a critical parameter for the material being welded—much like the temperature of a soldering iron: if the temperature is too low, the weld will not form; if too high, the raw material burns or its structure is damaged and strength suffers. Because each manufacturer selects different transducers, transducer output amplitudes differ; by matching boosters and horns with different gain ratios, the horn's working amplitude can be corrected to meet requirements. Transducer output amplitude is typically 10–20 μm, while working amplitude is generally around 30 μm. The gain ratio of the booster and horn depends on their shape and the ratio of front to rear face areas—shapes such as exponential, catenoidal, and stepped profiles strongly affect the gain, and the face-area ratio is proportional to the total gain. If you use welders from different brands, the simplest approach is to build the horn to the proportional dimensions of one that is already working, which ensures stable amplitude parameters.  
    2. Horn frequency parameter  
    Every ultrasonic welding machine has a center frequency, e.g. 20KHz, 40 KHz. The working frequency is mainly determined by the mechanical resonance frequency of the transducer, booster, and horn; the generator's frequency is tuned to match it so the horn works in resonance, with each part designed as a half-wavelength resonant body. The generator and mechanical resonance have a working range, typically set to ±0.5 KHz, within which the welder operates normally. When we manufacture each horn, we tune its resonance frequency so the error between resonance and design frequency is less than 0.1 KHZ—for example, for a 20KHz horn we control the frequency to 19.90—20.10 KHz, an error of 5‰.  
    3. Horn nodal point  
    The horn and booster are both designed as half-wavelength resonant bodies at the working frequency. During operation, amplitude is greatest and stress smallest at the two end faces, while at the nodal point in the middle the amplitude is zero and stress is greatest. The node is generally designed as the mounting position, but mounting designs are usually thicker than 3mm or use a groove mount, so the mounting position does not have exactly zero amplitude. This can cause some squealing and a degree of energy loss; squealing is usually isolated with rubber rings or shielded with sound-insulating materials, and energy loss is accounted for when designing the amplitude parameters.