1. The corrective action is to use an independent air supply; for work requiring accuracy below 0.02 mm, fit a stabilizing device on the ultrasonic machine; adjust the output power level to increase power. Under normal conditions, ultrasonic welding power output is best kept at levels 2–4; if operation at levels 5–6 is necessary, keep production time as short as possible to avoid damage to the parts and the transducers.
2. Increase the energy by enlarging the energy amplifier (the Horn upper tooling). But the enlargement ratio must not exceed 4:1 — going beyond that will seriously affect the Horn itself, the sound waves and the current, causing insufficient output energy from the ultrasonic machine. Keep this in mind.
3. When a small ultrasonic machine has to handle a large workpiece, use several weld passes, increase the ultrasonic output power (raise the power level), or increase weld time and pressure, so that the ultrasonic machine's output energy stays stable and sufficient.
PreviousFeatures of Automotive Glove Box Welding MachinesNextFour Key Precautions in Ultrasonic Mold Production